CURRENT INDUSTRIAL REPORTS Refrigeration, Air Conditioning, and Warm Air Heating Equipment - 1995 MA35M(95)-1 Issued August 15, 1996 Contact: Joanna T. Q. Nguyen, 301-457-4752 SCOPE OF SURVEY-This survey covers producers engaged in manufacturing refrigerati equipment, and nonelectric warm air furnaces. SURVEY METHODOLOGY-- The statistics in this publication are collected by mail on annual survey Form MA35M, Refrigeration and Air conditioning equipment, Includin The survey panel includes all known producers, approximately 277 companies. REVISIONS-Statistics for prior years may be revised as the result of corrected f late reports received for which imputations were originally made as described, or have been revised by more than 5 percent from previously published figures are in HISTORICAL NOTE-Data on air conditioning and refrigeration have been collected by since 1944. Historical data may be obtained from Current Industrial Reports (cal available at your local Federal Depository Library. A list of these libraries ma Bureau of Census regional offices. OBTAINING REPORTS-This report is available electronically through the Census-BEA Information on accessing the bulletin board can be obtained by calling 301-457-12 the Census Bureau's online information service, through DIALOG Information Servic COMPUSERVE 800-848-8199. For further information about CENDATA contact Customer Bureau of the Census, Washington, D.C. 20233, or call 301-457-1214. To order a FAX copy, call 1-900-555-2FAX from any touchtone phone and follow the is a charge of $2.50 per minute while ordering . The document will be delivered designate, anywhere in the U.S. For more information on FAX orders call 301-457- Table 1. SUMMARY OF SHIPMENTS OF REFRIGERATION, AIR-CONDITIONING, AND WARM AIR HEATING EQUIPMENT: 1995 AND 1994 (Value in thousands of dollars) Product Product description 1995 1994 code 35851 -- Heat transfer equipment....................... 6,170,943 r/5,802,366 35852 -- Unitary air-conditioners...................... 4,797,424 r/4,688,524 35853 pt. Commercial refrigeration equipment............ 202,628 220,257 35854 -- Compressors and compressor units.............. 4,306,689 3,790,885 35855 -- Condensing units, refrigeration (complete).... 286,415 277,479 35856 -- Room air-conditioners and dehumidifiers....... 1,266,882 1,105,844 3585c pt. Nonelectric warm air furnaces and humidifiers. 1,522,335 r/1,523,354 pt-- Partial. r/Revised by 5 percent or more from previously published figures. Table 2. QUANTITY AND VALUE OF SHIPMENTS OF REFRIGERATION, AIR-CONDITIONING AND WARM AIR HEATING EQUIPMENT: 1995 AND 1994 (Quantity in number of units; value in thousands of dollars) 1995 1994 Product Number of code Product description companies Quantity Value Quantity Value 35851 -- Heat transfer equipment, except room and unitary.... 155 (X) 6,170,943 (X) r/5,802,366 35851 01 Packaged terminal air-conditioners/1...................... 10 117,575 66,246 104,495 58,104 35851 03 Package terminal heat pumps............................... 9 94,843 50,148 r/83,099 r/43,631 Evaporative condensers.................................... (X) 2,353 52,727 2,724 49,803 35851 04 100 tons and under...................................... 7 526 4,309 747 4,269 35851 07 Over 100 tons........................................... 7 1,827 48,418 1,977 45,534 Room fan-coil air conditioning units...................... (X) 234,650 121,365 215,387 109,787 35851 08 Vertical stack.......................................... 4 9,541 6,898 24,498 8,484 35851 09 Vertical................................................ 8 114,999 68,640 97,064 63,129 35851 10 Horizontal.............................................. 8 110,110 45,827 93,825 38,174 35851 11 Room air induction units.................................. 2 (D) (D) (D) (D) Central station air-handling units (motor-driven fan type) (X) 336,207 492,828 r/280,053 r/429,088 35851 13 Draw through............................................ 24 315,723 428,628 r/258,438 r/359,437 35851 15 Blow through............................................ 13 7,942 41,295 9,850 46,978 35851 17 Heating and venelating.................................. 14 12,542 22,905 r/11,765 22,673 Coolers (refrigeration): Ceiling, wall-mounted, and floor-mounted unit coolers... (X) 194,278 140,129 187,572 122,190 35851 16 4,000 Btuh and below.................................. 11 61,014 12,773 61,202 14,188 35851 21 4,001 to 6,000 Btuh................................... 9 10,852 4,195 11,120 3,183 35851 22 6,001 to 8,000 Btuh................................... 8 17,956 7,128 r/19,906 r/7,041 35851 23 8,001 to 12,000 Btuh.................................. 9 42,091 21,736 38,938 18,033 35851 24 12,001 to 18,000 Btuh................................. 11 29,128 21,003 27,768 18,982 35851 25 Over 18,000 Btuh...................................... 14 33,237 73,294 28,638 60,763 Air cooled refrigerant condensers (remote type)......... (X) 29,420 56,566 27,938 57,933 35851 30 Under 30 tons......................................... 13 23,510 17,782 22,272 19,244 35851 32 30 to 50 tons......................................... 11 2,074 7,673 2,029 8,154 35851 34 Over 50 tons.......................................... 10 3,836 31,111 3,637 30,535 Miscellaneous heat transfer equipment: Shell- and-tube, shell-and-coil, shell-and-u-tube, tube- (X) (X) 66,997 (X) 64,831 35851 35 Condensers............................................ 9 (X) 38,664 (X) 38,258 35851 36 Liquid coolers........................................ 11 (X) 28,333 (X) 26,573 35851 37 Liquid-suction heat exchangers and refrigerant liquid re 6 (X) (D) (X) (D) Central system finned coils (air-conditioning and refrig (X) (X) 78,649 (X) 86,868 35851 38 Standard steam and steam distributing tube............ 14 (X) 14,517 (X) 13,876 35851 39 Standard water cooling and/or heating and cleanable tu 19 (X) 58,227 (X) 66,218 35851 40 Volatile refrigerant cooling.......................... 11 (X) 5,905 (X) 6,774 Coil sales by original equipment manufacturers intended resale or assembly into equipment by other manufacturer (X) (X) 372,485 (X) 385,305 35851 42 Copper and aluminum................................... 21 (X) 254,014 (X) 269,608 35851 43 Aluminum (only)....................................... 9 (X) 49,349 (X) 52,623 35851 46 Other (including steel,copper)........................ 10 (X) 69,122 (X) 63,074 35851 45 Factory-assembled, refrigeration type, finned gravity co including wetted-surface dehumidifiers................. 5 (X) 12,823 (X) 12,618 Centrifugal liquid chilling packages, hermetic and open ty (X) 10,087 766,410 r/7,661 r/562,420 35851 51 200 hp and under...................................... 8 1,487 46,301 r/1,303 r/ 38,328 35851 54 201 to 300 hp......................................... 5 1,850 98,240 1,297 r/ 64,774 35851 56 301 to 400 hp......................................... 5 1,548 97,594 r/1,112 r/ 70,290 35851 58 Over 400 hp........................................... 5 5,202 524,275 r/3,949 r/389,028 Ice making machines....................................... (X) 216,764 296,178 210,863 294,489 Self-contained ice-cube makers.......................... (X) 134,870 136,702 131,743 130,837 35851 62 Automatic, under 200 lbs ............................. 6 82,976 55,154 79,518 50,150 35851 64 Automatic, 201 lbs and over........................... 4 51,894 81,548 52,225 80,687 Self-contained flake or chip machines................... (X) 8,349 20,372 10,164 34,859 35851 68 300 lbs and under..................................... 4 4,186 5,101 5,481 6,277 35851 70 Over 300 lbs.......................................... 10 4,163 15,271 4,683 28,582 35851 71 Not self-contained...................................... 7 45,998 78,566 44,758 r/76,101 35851 75 Combination ice makers and ice/drink dispensers ........ 5 (D) 60,538 24,198 52,692 35851 74 Absorption refrigeration and dehydration systems.......... 7 2,395 112,814 2,138 81,815 35851 78 Mechanical refrigeration systems used on all types of vehicles................................................. 9 (D) (D) (D) (D) Mobile vehicle mechanical air-conditioning systems...... (X) 16,820,583 2,165,907 r/18,023,826 r/2,176,716 35851 79 Air- conditioning units and systems for passenger automobiles/2........................................ 20 11,955,462 1,365,991 13,511,488 1,435,773 35851 80 Air- conditioning units and systems for trucks, buses construction and agriculture machinery and other vehicles............................................. 18 4,865,121 799,916 r/4,512,338 r/740,943 Reciprocating air and reciprocating water cooled, air cooled, air cooled scroll, and water cooled scroll machines............................................... (X) 25,686 358,296 25,129 376,400 35851 91 20 hp and under....................................... 23 13,156 45,012 r/11,719 r/44,680 35851 93 21 to 49 hp........................................... 18 3,044 33,197 r/2,429 r/31,290 35851 95 50 to 75 hp........................................... 16 2,696 49,493 2,709 49,567 35851 97 Over 75 hp............................................ 15 6,790 230,594 8,272 250,863 35851 92 Factory-fabricated water cooling towers................. 11 8,948 147,365 r/9,409 132,842 35852 -- Unitary air-conditioners.............................. 60 (X) 4,797,424 (X) r/4,688,524 35852 10 Recreational vehicle air- conditioners.................... 6 (D) (D) (D) (D) Single package air- conditioners, with or without evaporat (including refrigeration chassis and remote-condenser type)...................................................... (X) 283,555 513,385 244,397 496,425 Horizontal.............................................. (X) 249,494 431,020 214,730 411,352 35852 31 Under 27,000 btuh..................................... 22 24,084 19,112 16,354 16,722 35852 32 27,000 to 32,999 btuh................................. 19 44,878 35,775 29,578 32,329 35852 33 33,000 to 53,999 btuh................................. 23 90,750 82,291 91,680 79,162 35852 34 54,000 to 64,999 btuh................................. 22 37,689 42,089 29,511 38,862 35852 35 65,000 to 96,999 btuh................................. 18 16,735 37,750 14,844 34,555 35852 36 97,000 to 134,999 btuh................................ 15 15,407 45,769 14,149 r/41,718 35852 37 135,000 to 184,999 btuh............................... 11 8,801 35,652 8,208 34,569 35852 38 185,000 to 249,999 btuh............................... 11 4,976 36,669 4,993 35,077 35852 39 250,000 to 319,999 btuh............................... 10 3,640 30,621 2,882 26,995 35852 40 320,000 to 379,999 btuh............................... 9 560 8,432 r/601 r/10,015 35852 41 380,000 btuh and over................................. 7 1,974 56,860 1,930 r/61,348 Other than horizontal................................... (X) 34,061 82,365 29,667 85,073 35852 4A Under 54,000 btuh .................................... 7 35852 44 54,000 to 64,999 btuh................................. 6 5,863 15,341 4,855 11,057 35852 45 65,000 to 96,999 btuh................................. 4 608 2,192 603 2,248 35852 46 97,000 to 134,999 btuh................................ 4 689 3,149 661 3,033 35852 47 135,000 to 184,999 btuh............................... 4 591 3,668 781 5,126 35852 4T 185,000 btuh and over................................. 6 1,010 25,684 1,007 29,433 Year- round air- conditioners, single package and remote-condenser type (except heat pumps).............. (X) 516,003 1,098,062 495,434 1,028,579 35852 50 Under 33,000 btuh..................................... 19 125,685 118,341 128,806 128,566 35852 51 33,000 to 38,999 btuh................................. 19 104,987 110,318 97,426 101,267 35852 52 39,000 to 43,999 btuh................................. 13 31,230 35,126 28,003 31,481 35852 53 44.000 to 53,999 btuh................................. 15 48,722 64,478 51,285 67,753 35852 54 54,000 to 64,999 btuh................................. 15 75,212 116,193 69,839 109,120 35852 55 65,000 to134,999 btuh................................. 14 83,388 244,675 77,517 220,660 35852 56 135,000 to 184,999 btuh............................... 12 24,790 131,975 22,725 118,950 35852 57 185,000 to 249,999 btuh............................... 12 12,123 93,623 10,917 85,921 35852 58 250,000 to 319,999 btuh............................... 11 5,964 62,098 4,953 51,525 35852 59 320,000 to 379,999 btuh............................... 10 1,024 17,723 1,158 r/20,633 35852 60 380,000 to 539,999 btuh............................... 8 975 21,063 1,308 27,377 35852 61 540,000 to 639,999 btuh............................... 9 554 20,229 581 19,544 35852 62 640,000 btuh and over................................. 8 1,349 62,220 916 45,782 Air source heat pumps (except room air-conditioners).... (X) 1,036,767 790,146 1,022,908 778,375 Single package: 35852 63 Under 27,000 btuh..................................... 17 24,907 21,030 24,868 20,392 35852 64 27,000 to 41,999 btuh................................. 15 73,229 75,979 74,934 75,149 35852 65 42,000 to 64,999 btuh................................. 15 48,719 60,381 r/45,892 57,590 35852 66 65,000 btuh and over.................................. 8 8,482 34,729 8,560 32,426 Split system: 35852 67 Under 27,000 btuh..................................... 16 285,165 140,463 264,469 130,536 35852 68 27,000 to 41,999 btuh................................. 16 404,889 273,913 408,255 278,692 35852 69 42,000 to 64,999 btuh................................. 15 177,984 156,733 184,073 159,454 35852 70 65,000 btuh and over.................................. 7 13,392 26,918 11,857 24,136 35852 71 Water source heat pumps (except room air-conditioners).. 14 109,326 120,378 99,321 105,771 Split system air- conditioning condensing units......... (X) 3,432,989 1,653,676 r/3,385,357 1,648,339 35852 72 Under 22,000 btuh..................................... 15 264,111 83,156 249,416 76,888 35852 73 22,000 to 26,999 btuh................................. 18 732,403 255,287 694,309 238,751 35852 74 27,000 to 32,999 btuh................................. 19 717,482 300,764 r/679,479 274,825 35852 75 33,000 to 38,999 btuh................................. 17 694,783 299,427 r/783,945 356,132 35852 76 39,000 to 43,999 btuh................................. 18 342,832 184,654 r/302,569 r/161,761 35852 77 44,000 to 53,999 btuh................................. 18 337,343 200,738 353,024 210,077 35852 78 54,000 to 64,999 btuh................................. 16 289,291 175,783 273,591 189,607 35852 79 65,000 to 96,999 btuh................................. 7 20,533 27,024 17,600 23,362 35852 80 97,000 to 134,999 btuh................................ 8 15,470 29,301 13,657 25,842 35852 81 135,000 to 184,999 btuh............................... 7 8,460 24,981 8,478 25,546 35852 82 185,000 to 249,999 btuh............................... 7 4,130 17,723 3,388 14,240 35852 83 250,000 to 319,999 btuh............................... 5 1,629 9,206 1,519 8,311 35852 84 320,000 to 379,999 btuh............................... 5 1,557 10,204 1,529 9,811 35852 85 380,000 to 539,999 btuh............................... 5 1,258 11,342 1,212 10,539 35852 86 540,000 to 639,999 btuh .............................. 4 614 6,552 629 6,590 35852 87 640,000 btuh and over................................. 4 1,093 17,534 1,012 16,057 Split system air-conditioning coils..................... (X) 2,744,237 509,443 2,744,968 519,481 35852 88 with blower........................................... 16 1,216,712 324,868 1,180,386 322,903 35852 89 Without blower........................................ 15 1,527,525 184,575 1,564,582 196,578 35853 43 Commercial refrigeration equipment, mechanical drinking water coolers............................................ 5 927,333 202,628 982,905 220,257 35854 -- Compressors and compressor units/3 /4................ 37 (X) 4,306,689 (X) 3,790,885 All refrigerants except ammonia........................... (X) 39,102,443 4,210,641 34,922,325 3,710,619 Hermetic-type motor compressors......................... (X) 22,484,099 2,440,446 19,653,536 2,105,384 35854 11 Under 3 hp............................................ 11 17,634,944 1,294,667 15,480,795 1,115,298 35854 23 3 to 10 hp............................................ 12 4,722,588 879,630 4,077,895 765,625 35854 30 15 hp................................................. 11 25,851 30,374 20,827 26,060 35854 32 20 hp................................................. 11 23,865 34,742 19,608 28,086 35854 34 25 hp................................................. 11 14,996 24,948 12,858 21,104 35854 36 30 hp................................................. 12 13,682 24,181 10,271 20,185 35854 39 40 hp and 50 hp....................................... 10 35854 42 60 hp................................................. 8 41,869 64,325 r/27,175 r/52,486 35854 46 75 hp................................................. 9 35854 49 100 hp and over ...................................... 7 6,304 87,579 r/ 4,107 r/76,540 35854 52 Open-type compressors (with or without motor--all sizes) 14 35854 53 Automotive air-conditioning compressors (open-type, with without motor) ........................................ 9 35854 54 Screw type.............................................. 3 16,618,344 1,770,195 15,268,789 1,605,235 35854 58 Ammonia refrigerants, all types........................... 8 2,838 96,048 2,502 80,266 35855 -- Condensing units, refrigeration (complete).......... 27 538,329 286,415 542,776 277,479 Air-cooled hermetic-type................................ (X) 526,413 198,456 524,021 177,624 35855 23 1 hp and under........................................ 16 442,416 101,627 444,911 91,717 35855 25 1.5 hp................................................ 14 18,352 13,686 18,801 10,845 35855 28 2 hp and 2.5 hp....................................... 14 23,602 16,201 18,540 14,996 35855 30 3 hp.................................................. 15 20,995 22,310 22,385 21,482 35855 32 Over 3 hp but under 15 hp............................. 17 21,048 44,632 19,384 38,584 35855 44 Water-cooled hermetic-type, under 15 hp................. 5 (D) (D) (D) (D) Water or air-cooled hermetic-type....................... (X) 4,224 42,421 4,293 55,271 35855 61 15 hp................................................. 6 1,793 21,782 r/2,123 26,364 35855 62 20 hp................................................. 6 783 4,401 876 7,861 35855 63 25 hp................................................. 7 348 2,539 r/286 2,715 35855 64 30 hp ................................................ 6 298 2,771 r/425 r/ 5,881 35855 70 40 hp................................................. 5 1,002 10,928 r/547 r/12,450 35855 80 Water or air-cooled open-type (all sizes)............... 8 35856 -- Room air-conditioners and dehumidifiers.............. 16 (X) 1,266,882 (X) 1,105,844 35856 11 Electrically operated dehumidifiers, mechanically refrigerated, self-contained........................... 10 (X) 152,269 (X) 127,610 Room air-conditioners................................... (X) 4,009,527 1,114,613 3,265,427 978,234 35856 31 5,999 btuh and under.................................. 4 879,010 161,265 658,107 123,571 35856 34 6,000 to 6,999 btuh................................... 6 236,127 54,859 205,141 49,348 35856 38 7,000 to 7,999 btuh................................... 6 452,980 95,123 343,566 86,826 35856 42 8,000 to 8,999 btuh................................... 5 257,206 70,385 257,761 68,318 35856 46 9,000 to 9,999 btuh................................... 6 59,690 20,482 39,573 14,758 35856 52 10,000 to 10,999 btuh................................. 6 506,087 135,466 r/420,696 r/115,303 35856 56 11,000 to 12,999 btuh................................. 8 711,583 192,453 519,028 162,806 35856 61 13,000 to 14,999 btuh................................. 7 76,984 28,982 66,181 29,125 35856 63 15,000 to 16,999 btuh................................. 7 63,114 25,429 51,785 21,783 35856 65 17,000 to 19,999 btuh................................. 7 460,919 173,775 414,527 158,026 35856 67 20,000 to 22,999 btuh................................. 5 34,552 16,259 35,730 17,216 35856 68 23,000 to 25,999 btuh................................. 9 233,149 107,345 210,150 96,173 35856 69 26,000 btuh and over.................................. 10 38,126 32,790 43,182 34,981 3585c pt Nonelectric warm air furnaces and dehumidifiers......... (X) (X) 1,522,335 (X) r/1,523,354 Oil, forced air: 3585c 04 150,000 btu bonnet output and under................. 22 214,140 120,517 250,553 137,470 3585c 13 150,001 btu bonnet output and over.................. 17 7,212 9,664 8,234 11,142 Gas, forced air: 3585c 07 150,000 btu bonnet output and under................. 25 2,635,429 1,159,771 2,672,615 1,163,775 3585c 08 150,001 - 400,000 btu bonnet output................. 17 (D) 18,646 (D) 20,837 3585c 09 Over 400,000 btu bonnet output...................... 12 (D) 146,567 (D) r/124,936 3585c 79 All other nonelectric warm air furnaces............... 6 1,146 1,320 1,465 1,847 3585c 20 Humidifiers (attachments to warm air furnaces) all types central systems and self-contained, except portable humi 22 565,004 65,850 579,233 63,347 - Represents zero. (D) Data withheld to avoid disclosing figures for individual companies. pt. Partial. r/Revised by 5 percent or more from previously published figures. (X) Not applicable. BTUH (British Thermal Units -per hour) 1/Defined as factory selected combinations of heating and cooling components or assemblies intended to serve an individual room and comprising: (1) hearing assembly available with element for use with hot water, steam, and electricity; means for forced heated air cir- culation and distribution; integral or remote temperature controls; (2) slide-in cooling section with complete refrigerant cycle; (3) ro cabinet; (4) provision for outdoor air intake and discharge and accessories as required for mounting in a building wall; (5) provisions air filtration and ventilation; (6) permanent individual branch circuit wiring with a suitable line cord or terminating at a junction bo within the room cabinet; and (7) provision for free conditioned air distribution, or when forced circulation is employed for minimal duc work having a total external static resistance not exceeding 1/10 inch of water. 2/Figures exclude systems assembled from purchased components and installed at passenger automobile assemby lines. The values are understated for some systems because of the exclusion of compressors. 3/Represents only those compressors and copressor units produced and shipped separately, including interplant transfers. 4/Includes units shipped for household refrigerators. Table 3. QUANTITY OF ASSEMBLED COMPRESSOR BODIES: 1995 AND 1994 (Quantity in number of units) Product description Number of companies 1995 1994 Compressor bodies 1/ 2/.............................. (X) 33,195,629 30,959,021 All refrigerants, except ammonia.......................... (X) 33,194,921 30,958,332 Other than automotive air-conditioning.................. (X) 22,095,789 20,014,461 1/4 hp.and under...................................... 5 5,825,347 5,420,787 1/3 hp and 1/2 hp AND................................. 6 3/4 hp.and 1 hp....................................... 4 4,942,711 4,021,049 1 1/2 hp.............................................. 5 880,010 r/991,282 2 hp.................................................. 6 4,851,194 4,354,485 3 hp.................................................. 10 2,650,997 2,514,514 4 hp AND.............................................. 5 5 hp.................................................. 6 2,153,683 1,916,268 7 1/2 hp.............................................. 9 278,270 308,503 10 hp................................................. 11 317,984 265,317 15 hp................................................. 9 60,557 108,077 20 hp................................................. 9 34,893 31,100 25 hp................................................. 9 17,107 20,944 30 hp................................................. 10 21,387 20,618 40 hp................................................. 10 28,913 25,830 50 hp................................................. 5 60 hp AND............................................. 7 24,861 9,093 75 hp................................................. 6 1,372 1,889 100 hp. and over...................................... 6 6,503 4,705 Automotive air-conditioning, (including passenger auto- mobiles, trucks, buses, agriculture and construction equipment)............................................. 4 (D) (D) Ammonia refrigerants...................................... 5 (D) (D) r/Revised by 5 percent or more from previously published figures. (X) Not applicable. 1/Includes units for household refrigerators. 2/Represents the total number of compressor bodies assembled, whether shipped separately or incorporated into a condensing package or unitary end-use product, such as single package air-conditioners freezers, and refrigerators (manufactured and remanufactured units). Table 4. COMPARISON OF VALUES OF SHIPMENTS OF REFRIGERATION, AIR-CONDITIONING,AND WARM AIR HEATING EQUIPMENT AS REPORTED IN THE MA35M, THE 1994 ANNUAL SURVEY OF MANUFACTURES (Value in milllions of dollars) 1994 Annual Product Product description 1994 Survey of code MA35M Manufactures/1 3585-- Refrigeration and heating equipment................... (X) 22,439.0 35851 Heat transfer equipment............................... 5,802.4 5,650.5 35852 Unitary air-conditioners.............................. 4,688.5 4,483.4 35853 Commercial refrigerators and related equipment........ (2) 2,171.3 35854 Compressors and compressor units, all refrigerants.... 3,790.9 3,905.9 35855 Refrigeration condensing units........................ 277.5 253.0 35856 Room air-conditioners and dehumidifiers............... 1,105.8 1,183.1 35859 Refrigeration and air-conditioning equipment n.e.c.... (2) 813.8 3585C pt. Nonelectric warm air furnaces and humidifiers......... 1,523.4 1,827.3 3585D Parts for refrigeration and heating equipment......... (2) 1,852.5 35850 00 Refrigeration and heating equipment n.s.k............. (2) 298.4 N.e.c. Not elsewhere classified. N.s.k. Not specified by kind. pt. Partial. (X) Not applicable. 1/Source: 1994 Annual Survey of Manufactures, (Value of Product Shipments), M94(AS)-2. 2/Data for this product class is collected only in the Census of Manufactures and Annual Survey of Manufactures. Table 5. SHIPMENTS, EXPORTS, IMPORTS, AND APPARENT CONSUMPTION OF AIR-CONDITIONING AND REFRIGERATION EQUIPMENT: 1995 AND 1994 (Value in thousands of dollars) Exports of domestic merchandise/1 Manufacturers' shipments Estimated Imports for Product Product description (value f.o.b. Value at producers' consumption code/1 plant) port/2 value/3 4/ 5/ 1995 35851 Heat transfer equipment, (excluding room and unitary air-conditoners and dehumidifiers).................... 6,170,943 757,880 568,562 42,554 35852 Unitary air-conditioners.............................. 4,797,424 298,377 223,842 43,879 35853 43 Commercial refrigeration equipment, mechanical drinking water coolers................................ 202,628 26,147 19,615 2,479 35854 Compressors and compressor units, all refrigerants.... 4,306,689 817,714 613,449 753,526 35855 Condensing units, all refrigerants.................... 286,415 20,695 15,525 19,040 35856 Room air-conditioners and dehumidifiers............... 1,266,882 142,835 107,155 368,664 3585C pt. Nonelectric warm air furnaces and humidifiers......... 1,522,335 (NA) (NA) (NA) 1994 35851 Heat transfer equipment, (excluding room and unitary air-conditioners and dehumidifiers)................... r/5,802,366 494,915 371,285 41,096 35852 Unitary air-conditioners.............................. r/4,688,524 302,290 226,778 57,922 35853 43 Commercial refrigeration equipment, mechanical drinking water coolers................................ 220,257 23,758 17,823 1,685 35854 Compressors and compressor units, all refrigerants.... 3,790,885 711,776 533,974 722,336 35855 Condensing units, all refrigerants.................... 277,479 15,700 11,778 13,955 35856 Room air-conditioners and dehumidifiers............... 1,105,844 101,888 76,436 286,017 3585C pt. Nonelectric warm air furnaces and humidifiers......... r/1,523,354 (NA) (NA) (NA) (NA) Not available. r/ Revised by 5 percent or more from previously published figures. pt/. partial. 1/ Source: Bureau of the census report EM 545,(U.S. Exports) (see table 6 for a comparison of SIC-Based codes and import and export numbers). 2/ This dollar value represents the c.i.f. (cost, insurance, and freight) value at the port of export. 3/ These values were derived by use of adjustment factors to exclude freight, insurance, and other charges incurred in moving goods to the port of export. This adjustment is made to convert the values to an approximation of the producers' value of exported goods. Current adjustment factors are based on data for 1995 which are published (in Exports from Manufacturing Establishments), AR89-1. appendix b. The adjustment factor for this report is 0.7502. 4/ Source: Bureau of the Census report IM 145, (U.S. Imports for Consumption). These figures include both import value and duty value. 5/ Represents the C.I.F. (cost, insurance, and freight) value at the first port of entry in the United States plus U.S. import duties. Table 6. COMPARISON OF STANDARD INDUSTRIAL CLASSIFICATION-BASED PRODUCT CODES WITH SCHEDULE B EXPORT NUMBERS, AND HTSUSA IMPORT NUMBERS: 1995 Product Export Import code Product description number/1 number/2 8415.82.0030 8415.82.0030 8415.82.0035 8415.82.0035 8415.83.0040 8415.83.0040 8418.69.0010 8418.69.0010 35851 Heat transfer equipment............................ 8418.69.0015 8418.69.0015 8418.69.0045 8418.69.0045 8418.69.0050 8418.69.0050 8418.69.0055 8418.69.0055 8418.69.0060 8418.69.0060 8415.81.0010 8415.81.0010 8415.81.0020 8415.81.0020 8415.81.0030 8415.81.0030 8415.82.0005 8415.82.0005 8415.82.0010 8415.82.0010 35852 Unitary air-conditioners (except room)............. 8415.82.0015 8415.82.0015 8415.82.0020 8415.82.0020 8415.82.0025 8415.82.0025 8415.83.0050 8415.83.0050 8415.83.0060 8415.83.0060 35853 43 Mechanical drinking water coolers.................. 8418.69.0020 8418.69.0020 8414.30.4000 8414.30.4000 8414.30.8010 8414.30.8010 8414.30.8020 8414.30.8020 8414.30.8030 8414.30.8030 35854 Compressors and compressor units................... 8414.30.8050 8414.30.8050 8414.30.8060 8414.30.8060 8414.30.8070 8414.30.8070 8414.30.8080 8414.30.8080 8414.30.8090 8414.30.8090 8418.99.0005 8418.99.8005 8418.99.0010 8418.99.8010 35855 Refrigeration condensing units..................... 8418.99.0015 8418.99.8015 8418.99.0020 8418.99.8020 8418.99.0025 8418.99.8025 8415.10.0040 8415.10.0040 35856 Room air-conditioners and dehumidifiers............ 8415.10.0060 8415.10.0060 8415.10.0080 8415.10.0080 8415.82.0050 8415.82.0055 8415.82.0060 3585C Nonelectric warm air furnaces and humidifiers...... 3/ 3/ 1/Source: Schedule B, Statistical Classification of Domestic and Foreign Commodities Exported from the United States, 1995. 2/Source: Harmonized Tariff Schedule of the United States, 1995 3/Import/Export classification not directly comparable. rs). 2/ This dollar value re